DCC-10 is an EV Energy Management System specifically designed to allow the connection of an charging unit to a panel that is at full capacity and would otherwise need an upgrade.
Requires one double pole breaker slot available in the panel, contrary to DCC-9.
OPERATION
-
Real-time reading of the total power consumption of the electrical panel
-
Detects when the total power consumption exceeds 80% of a main circuit breaker capacity and temporarily de-energizes the charger
-
Automatically re-energizes the charger when the total power consumption of the main circuit breaker capacity is less than 80% for more than 15 minutes
FEATURES
-
Does not affect the load calculation of a panel
-
Can be mounted on the wall or ceiling
-
Avoids the need for a panel upgrade
- NEMA-3R enclosure allows for an outdoor installation
Included: Charge Controller, EV Charger Breaker (Max 60A) and Split Core current transformers (CT).
Gen-3 of the DCC-10 has the ability to receive and transmit load shedding instructions from an external energy management system via a dry contact input and output.
Download the DCC-10 Specification Sheet
Download the DCC-10 Installation Manual
INSTALLATION VIDEO